Echogenicity and ultrasound visibility of peripheral nerves of the upper extremity

Lori A. Stolz

1

, Josie G. Acuña

2

, Kevin Gaskin

3

, Amanda M. Murphy

2

, Lucas Friedman

4

, Summer Stears-Ellis

5

, Parisa Javedani

6

, Uwe Stolz

1

, Srikar Adhikari

2

1Department of Emergency Medicine, The University of Cincinnati, Cincinnati, Ohio, 2Department of Emergency Medicine, The University of Arizona, Tucson, Arizona, 3Department of Emergency Medicine, Upstate Medical Uni- versity, State University of New York, Syracuse, New York, 4Riverside community Hospital, Riverside, California,

5Kaiser Permanente, Portland, Oregon, 6Tucson Medical Center, Tucson, Arizona, USA

Received 07.09.2017 Accepted 16.01.2018 Med Ultrason

2018, Vol. 20, No 2, 199-204

Corresponding author: Josie G. Acuña, MD, Assistant Professor Department of Emergency Medicine, The University of Arizona

1501 N. Campbell Ave, AHSL, 4th floor Tucson, AZ 85724

Phone: (520) 626-9604, Fax: 520-626-2480 E-mail: [email protected]

Introduction

Ultrasound-guided peripheral nerve blocks are used with increasing frequency to manage pain in a variety of hospital settings. A successful ultrasound-guided pe- ripheral nerve block hinges on adequate visualization

of the targeted nerve. Physicians performing regional anesthesia could save time and resources if they could identify a priori patient characteristics that would pre- dict a more difficult ultrasound depiction of peripheral nerves. Nerves that are difficult to visualize makes the procedure more challenging to perform and could poten- tially lead to complications, failure to perform the pro- cedure, or decreased success. Prior research documents the common anatomical appearance of the target nerves by ultrasound in healthy subjects and in states of pathol- ogy such as neuropathy, nerve damage or disease [1-4].

These studies have identified that the echogenicity of nerves changes based on ratio of total fascicular area to whole nerve area and fascicle pattern [5]. Since myelin sheaths are lipid-based, it is possible that increased body Abstract

Aim: Regional anesthesia with ultrasound-guidance is an excellent option for pain control if nerves are adequately visual- ized. Gender, body mass index (BMI), history of diabetes, neck and forearm circumference may affect echotexture and visu- alization. This study evaluates patient characteristics for their ability to predict the echogenicity or visibility of upper extremity peripheral nerves. Material and methods: This is a prospective observational study. A convenience sample of adult emer- gency department patients were enrolled. Gender, BMI, history of diabetes, neck circumference and arm circumference were recorded. Sonographic images of the brachial plexus at interscalene and supraclavicular levels, the median, the radial and ulnar nerves were recorded. Three reviewers independently graded the echogenicity and visibility using subjective scales. Results:

395 peripheral nerves were included. Nerves of the forearm (median, ulnar, radial nerves) were found to be more echogenic (OR=9.3; 95% CI: 5.7, 15.3) and visible (OR=10.0; 6.3, 16.0) than more proximal nerves (brachial plexus at interscalene and supraclavicular levels). Gender, BMI, and history of diabetes mellitus were not significantly related to nerve visibility (p=0.9, 0.2, 0.2, respectively) or echogenicity (p=0.3, 0.8, 0.3). Neck circumference was not related to visibility or echogenicity of proximal nerves. Increased forearm circumference improved echogenicity (OR=1.25; 1.09, 1.43) but not visibility of forearm nerves. Conclusions: Gender, BMI and presence of diabetes were not related to echogenicity or visibility of upper extremity nerves. Increasing forearm circumference was associated with increased echogenicity of the adjacent nerves, but not visibility.

Neck circumference was not associated with either nerve visibility or echogenicity of brachial plexus nerve bundles.

Keywords: Ultrasonography; nerve block; peripheral nerve injection; regional anesthesia

(2)

mass index (BMI) could confer increased echogenicity of a nerve, leading to improved visibility. Traditionally, however, increased BMI and increased depth to tar- get structures leads to poor sonographic visualization.

In addition to BMI, another factor known to affect the sonographic visualization of nerves is the presence of diabetes. Watanabe et al[6] found a significant increase in the cross-sectional area and in the hypoechoic aspect of the nerves in diabetic patients when compared with controls. This is due to increased water content related to increased aldose reductase conversion of glucose to sorbitol, local ischemia from microvascular injury, and interference with the innate metabolism of the periph- eral nerves in diabetic patients [7-8]. Similarly, several small studies exist that have addressed the varying so- nographic appearance of nerves with respect to gender.

Multiple studies have noted a difference in the cross- sectional area of peripheral nerves, with those in females being significantly smaller [9-10]. While it is known that various patient characteristics have an effect on the so- nographic appearance of nerves, there appears to be a gap in the current literature in regards to which of these have a significant effect on the nerve visualization nec- essary for providing ultrasound-guided regional anes- thesia.

This study aims to identify patient characteristics that could predict difficult peripheral nerve visualization. Our hypothesis is that certain patient physical characteristics (neck and forearm circumference, gender) as well clinical history (diabetes, obesity) can predict the echogenicity and visibility of peripheral nerves of the upper extremity.

Material and methods

This is a prospective observational study. The Uni- versity of Arizona Institutional Review Board approved this study. Written informed consent was obtained from all subjects. A convenience sample of adults (>18 years old) presenting to an academic emergency department

were enrolled after consent process. Subjects with altered mental status, acute anxiety state or hemodynamic or res- piratory instability were excluded. Also, subjects were excluded if they were unable to sit in a semi-reclined po- sition for ultrasound examination.

Data collection and ultrasound examinations were performed by study personnel consisting of emergency medicine residents and attending physicians. Two senior- level resident physicians and four attending physicians performed the ultrasound examinations and captured im- ages. Resident physicians had previously taken a stand- ardized 8 hour course on emergency ultrasonography that included a 4 hour lecture and 4 hours of hands-on train- ing. They also completed a 2 week emergency ultrasound elective and performed approximately 400 point-of-care ultrasound examinations. The attending physicians had emergency ultrasound fellowship training experience and performed approximately 900 point-of-care ultra- sound examinations. The attending physicians routinely used bedside ultrasound in the emergency department for patient care. Patient characteristics including gender, BMI, and past medical history of diabetes were recorded from the electronic medical record and clarified with sub- jects. Neck circumference was measured with a standard tape measure at the level of the cricoid cartilage. Forearm circumference was measured at the widest portion of the forearm.

Prior to data collection, study physicians reviewed sonographic anatomy of the nerves of the upper extrem- ity. The study protocol for image acquisition utilized a high-frequency linear transducer (12-4 MHz) and a Phil- lips Sparq ultrasound machines (Andover, MA). Study personnel were instructed to optimize images to obtain the best possible image as if they would be performing a peripheral nerve block. Cross-sectional (transverse plane) images of the brachial plexus at interscalene level and supraclavicular level, as well as the radial, median and ulnar nerves at the level of the mid-forearm, were obtained and recorded (fig 1).

Fig 1. Sonographic images of the peripheral nerves of the upper extremity and neck evaluated in this study (a) Interscalene brachial plexus, b) supraclavicular brachial plexus, c) median nerve at the level of the mid-forearm, d) radial nerve at the level of the mid- forearm, e) ulnar nerve at the level of the mid-forearm).

(3)

Three reviewers blinded to patient data independently graded the echogenicity and visibility of each nerve from recorded images. These reviewers were emergency phy- sicians with advanced training in emergency ultrasound.

They graded the echogenicity of each nerve using a four- point subjective echogenicity index (SEI) (Table I). This previously published index performed well against gray- scale image measurements [5]. Visibility was assessed using a five-point Likert scale adapted from a previous study assessing sonographic visibility of structures for procedures (Table II) [11]. Prior to image review, review- ers studied a collection of sample images representing the range of possible grades for each scale. All three re- viewers graded a 20% overlapping sample so that inter- rater reliability could be assessed.

Data Analysis

Statistics were calculated using Stata (version 14, Stata Corp, College Station, TX). Means (95% confi- dence intervals [CIs]), medians (interquartile range), and percentages (95% CIs) are used for descriptive data.

Our power and sample size calculation assumed the analysis would use linear regression; however, our outcome variables (echogenicity and visibility) were not normally distributed. Thus, we used random-effects ordered logistic regression (ideal for continuous ordi- nal outcomes) to assess the relative odds of each unit increase in the outcome variables (echogenicity and vis- ibility) for the following independent variables: Nerve location, neck circumference for neck nerves, forearm circumference for forearm nerves, BMI, and presence of diabetes mellitus, and sex. Each subject was considered a cluster. We used the final regression models for echo- genicity and visibility to estimate the predicted (margin- al) probability of each outcome stratified by nerve loca- tion and used goodness of fit tests for ordered logistic

regression to assess the final fit of all models [12]. We used fractional polynomial regression to determine if continuous independent variables were linearly related to the outcome variables in the log odds (logit) scale. We calculated inter-rater reliability (kappa) for the three re- viewers. We used a weighted kappa with weights for the difference between reviewer scores as the square of the difference. In other words, a difference of 1 had a lower weight than a difference of 2. For the main analysis, we only used one randomly chosen reviewer’s ratings for the subset of samples utilized for interrater reliability analysis.

Sample size

Our study was powered (power=0.8) to detect an R2 value of 0.1 for one key predictor variable with a total R2 of 0.25 for all variables in a linear regression model with 4 other independent variables. The following 5 independ- ent variables were chosen a priori: BMI, neck circum- ference, forearm circumference, nerve location, and sex) with an alpha = 0.05. We had sufficient power to include 5 independent variables in a linear regression model and detect an R2 of 0.1 for one predictor variable and an R2 of .25 overall (i.e., one independent variable would explain 10% of the variance in the dependent variable and the other 4 variables would explain an additional 15% of the variance). A sample size of 73 was required to achieve the power stated above and we chose 80 subjects to ac- count for missing data. An R2 value of 0.25 for up to five variables is a modest effect size and thus is reasonable given our study goals to identify potentially significant predictors of nerve visualization using ultrasound. This effect size is a clinically relevant number since account- ing for 25% of the variance overall (and 10% of the vari- ance with one predictor) in nerve echogenicity would be a clinically significant finding.

Table I. Subjective echogenicity index for grading peripheral nerve echogenicity [5]

Grade Definition

0 Cannot visualize nerve

1 Hypoechoic (echogenicity of a muscle belly) 2 Mixed echogenicity (typical honeycomb appearance) 3 Hyperechoic (echogenicity of an intermuscular septum)

Table II. Subjective visibility scale 5-point Likert scale for grading peripheral nerve visibility [11]

Grade Definition

1 Cannot visualize the nerve

2 The nerve can be located, but visualization is poor and using this image for performing a nerve block would be very difficult.

3 An adequate view was obtained but a better image of the nerve might be desired for a nerve block.

4 A good view was obtained and the reviewer would feel comfortable performing a nerve block.

5 An excellent view was obtained and this is an optimal image for using for performing a nerve block.

(4)

Results

A total of 80 subjects were enrolled. One subject’s data was not analyzed due to missing data. Nerves at five sites were analyzed for each subject for a total of 395 nerves. The median BMI was 26 (IQR: 23-31). Of the subjects whose data was analyzed, 13.9% (95% CI: 7.2, 23.5) had a history of diabetes and 44.2% (29.1, 60.1) of subjects were male. The mean neck circumference was 38.3 cm (37.0, 39.6) and the mean forearm circumfer- ence was 24.9 cm (24.0, 25.8).

Neither BMI, gender, nor presence of diabetes mel- litus was significantly related to nerve visibility (p=0.9, 0.2, 0.2, respectively) or echogenicity (p=0.3, 0.8, 0.3, respectively), after controlling for differences among nerves.

Forearm nerves (radial, median, ulnar) as a group had significantly higher echogenicity and visibility compared to brachial plexus nerves (at interscalene and supraclav- icular level) with p<0.001. The predicted (i.e. marginal) probability of each individual echogenicity (0, 1, 2, or 3) and visibility (1, 2, 3, 4, or 5) score for each nerve site, calculated from the final logistic regression mod- els, can be seen in figures 2 and 3, which show that the forearm nerves as a group have higher echogenicity and visibility on average compared to the nerves of the neck.

Forearm nerves had 9.3 times higher odds of a higher echogenicity score (95%CI: 5.7, 15.3) and 10.0 times higher odds of a higher visibility score (95%CI: 6.3, 16.0) compared to the nerves of the neck. Forearm cir- cumference was significantly related to echogenicity for the 3 forearm nerves, with each 1 cm increase in forearm circumference being associated with an increase in the

odds of a higher echogenicity (OR=1.25; 95%CI: 1.09, 1.43). The radial nerve had a higher echogenicity com- pared to both the median (OR=2.7; 95% CI: 1.3, 6.0) and ulnar (OR=2.3; 95%CI: 1.1, 4.9) nerves, which did not differ significantly from each other (p=0.64). Forearm circumference was not significantly related to visibility for the 3 forearm nerves [OR per 1 cm = 1.16 (95%CI:

0.96, 1.40)]. For the forearm nerves, both ulnar (OR=2.5;

95%CI: 1.2, 5.0) and median (OR=2.2; 95%CI: 1.1, 4.4) nerves had higher odds of improved visibility compared to the radial nerve, but the ulnar and median nerves did not differ significantly from each other (p=0.72).

Neck circumference was not related significantly to echogenicity (OR per 1 cm increase in circumference = 0.9; 95%CI: 0.8, 1.0) or visibility (OR=1.0; 95%CI: 0.9, 1.1) for the nerves of the neck. In addition, the brachial plexus at supraclavicular level did not differ significantly from the brachial plexus at interscalene level for either echogenicity (OR=0.8; 95%CI: 0.4, 1.6) or for visibility (OR=0.7; 95%CI: 0.4, 1.2).

The inter-rater reliability (kappa statistics) for echo- genicity and visibility was calculated among three inde- pendent reviewers for a 20% random sample of all obser- vations (N=80) and showed that reviewers had moderate agreement [13]. For echogenicity, paired kappas were 0.491 (95%CI: 0.292 - 0.653), 0.597 (0.425 - 0.758), and 0.414 (0.309 - 0.526), while for visibility, paired kappas were 0.483 (0.363 - 0.611), 0.595 (0.441 - 0.748), and 0.447 (0.266 - 0.591).

All final ordinal logistic regression models met the assumption of proportional odds across outcome catego- ries as well as having adequate fit, with all p-values for goodness of fit tests >0.05.

Fig 2. This bar graph depicts the probability of each possible echogenicity score (0 to 3) for each nerve of the neck and fore- arm evaluated in this study based on the final logistic regression model.

Fig 3. This bar graph depicts the probability of each possible visibility score (1 to 5) for each nerve of the neck and forearm evaluated in this study based on the final logistic regression model.

(5)

Discussions

Echogenicity and visibility vary by nerve with the peripheral nerves of the forearm, median, ulnar, and ra- dial nerves being significantly more echogenic and more visible than the brachial plexus nerves. The differences in echogenicity between peripheral and proximal nerves have been well-documented in prior literature [14].

Nerves located more peripherally are both easier to visu- alize and farther from other structures to be avoided. This is predominantly due to the differences in the area of con- nective tissue to the area of fascicle in the nerve bundle.

This study adds to the prior literature by attempting to identify patient characteristics that could predict difficult nerve visualization.

Neither patient gender nor BMI had any effect on vis- ibility or echogenicity for any of the nerves. While cli- nicians may use the patient’s body habitus to determine whether a nerve block should be attempted, BMI was not significantly predictive of nerve visibility or echogenic- ity in this study’s population. Notably, the study popu- lation was, on average, overweight with a median BMI of 26. Forearm circumference was significantly related to echogenicity of the forearm nerves, with higher echo- genicity associated with increasing circumference. This could be related to the increased proportion of myelin sheath to the nerve volume in more peripheral nerves and increased myelin (fat) associated with greater circumfer- ence. This aspect of our findings requires further study.

Notably, visibility of the nerves was not related to neck or forearm circumference, therefore a clinicians’ assess- ment of a patient’s size may not predict success in visual- izing nerves.

Diabetes can cause several nerve disorders that can change the sonographic appearance of peripheral nerves.

The most common of these is diabetes-related polyneu- ropathy which is visualized sonographically as increased circumference and loss of the fascicular pattern of the af- fected nerves [15]. Our study detected no change in echo- genicity or visualization based on a past medical history of diabetes, indicating that this factor was not clinically relevant in our study population. The underlying preva- lence of diabetic-related neuropathy in our study popula- tion is unknown. It is possible that with a larger sample size and with a study population that encompasses the full spectrum patients with and without a diabetes-related neuropathy, it would be possible to detect a change in visibility or echogenicity of the nerves.

To our knowledge, this was the first study to explore patient characteristics that could predict peripheral nerve visualization in the emergency department patient popu- lation. Peripheral nerve images were obtained by clini-

cians with varied ultrasound experience reflecting real- word clinical practice setting. To make this study robust, we trained study physicians in sonographic anatomy of the peripheral nerves of the upper extremity and also used previously published echogenicity index to avoid any discrepancies in grading the peripheral nerve images.

In addition, we studied peripheral nerves most common- ly used to provide ultrasound guided regional anesthesia by clinicians practicing in the acute care settings.

Our study is limited by convenience sampling and the subjective nature of the grading scales used. Whereas some research has found that subjective grading of echo- genicity leads to similar results as quantitative analysis, other research has found it inferior to quantitative gray- scale, computer-driven analysis [5,16].Another limita- tion of this study is in regards to the level of training and scanning experience of the physicians that performed the scout scans. The scout scans were performed by both res- idents and attending physicians who had varied levels of experience in ultrasound. This heterogeneity constitutes a limitation of the study as it had significant influence on the quality of the acquired images. We did not obtain information on whether the patients had neuropathy or prior procedures or injuries affecting the examined re- gion. Nor did we record whether the patients with diabe- tes had experienced any neurological symptoms. In addi- tion, the study was powered to detect the threshold effect size that we had set and any changes with diabetes were not sufficient to detect a correlation. We also did not per- form neurological examination on our subjects. Had such patient information been obtained, our results may have been more robust.

In conclusion, we have found peripheral nerves of the forearm to be more echogenic and more visible than those of the neck. While BMI and diabetes do not affect visualization or echogenicity of nerves, increasing fore- arm circumference was associated with increased nerve echogenicity.

Conflict of interest: None

References

1. Jacobson JA, Wilson TJ, Yang LJ-S. Sonography of Com- mon Peripheral Nerve Disorders With Clinical Correlation.

J Ultrasound Med. 2016;35:683-693.

2. Kowalska B, Sudol-Szopinska I. Normal and sonographic anatomy of selected peripheral nerves. Part II: Peripheral nerves of the upper limb. J Ultrason. 2012;12:131-147.

3. Kowalska B, Sudol-Szopinska I. Normal and sonographic anatomy of selected peripheral nerves. Part I: Sonohistol- ogy and general principles of examination, following the example of the median nerve. J Ultrason. 2012;12:120-130.

(6)

4. Lapegue F, Faruch-Bilfeld M, Demondion X, et al. Ultrasonog- raphy of the brachial plexus, normal appearance and practical applications. Diagn Interv Imaging. 2014;95:259-275.

5. Lee SH, Lee SH, Chan VW, Lee JO, Kim HI. Echotex- ture and correlated histologic analysis of peripheral nerves important in regional anesthesia. Reg Anesth Pain Med.

2011;36:382-386.

6. Watanabe T, Ito H, Sekine A, et al. Sonographic evaluation of the peripheral nerve in diabetic patients: the relation- ship between nerve conduction studies, echo intensity, and cross-sectional area. J Ultrasound Med, 2010; 29:697-708.

7. Liu MT, Lee JT, Wang CH, Li YC, Chou CH. Cubital tunnel syndrome caused by ulnar nerve schwannoma in a patient with diabetic sensorimotor polyneuropathy. Acta Neurol Taiwan, 2016;25:60–64

8. Lee D, Dauphinée DM. Morphological and functional chang- es in the diabetic peripheral nerve: using diagnostic ultra- sound and neurosensory testing to select candidates for nerve decompression. J Am Podiatr Med Assoc, 2005;95:433–437 9. Kerasnoudis A, Pitarokoili K, Behrendt V, Gold R, Yoon MS. Cross sectional area reference values for sonography of peripheral nerves and brachial plexus. Clin Neurophysi- ol. 2013;124:1881-1888.

10. Cartwright MS, Shin HW, Passmore LV, Walker FO. Ultra- sonographic findings of the normal ulnar nerve in adults.

Arch Phys Med Rehabil. 2007;88:394-396.

11. Stachura MR, Socransky SJ, Wiss R, Betz M. A comparison of the supraclavicular and infraclavicular views for imag- ing the subclavian vein with ultrasound. Am J Emerg Med.

2014;32:905-908.

12. Fagerland MW, Hosmer DW. Tests for goodness of fit in ordinal logistic regression models. J Stat Comput Simul.

2016;86:3398-3418.

13. Viera AJ, Garrett JM. Understanding interobserver agree- ment: the kappa statistic. Fam Med. 2005;37:360-363.

14. Moayeri N, Bigeleisen PE, Groen GJ. Quantitative archi- tecture of the brachial plexus and surrounding compart- ments, and their possible significance for plexus blocks.

Anesthesiology. 2008;108:299-304.

15. Gallardo E, Noto YI, Simon NG. Ultrasound in the diag- nosis of peripheral neuropathy: structure meets function in the neuromuscular clinic. J Neurol Neurosurg Psychiatry.

2015;86:1066-1074.

16. Cheng JW, Tsai WC, Yu TY, Huang KY. Reproducibility of sonographic measurement of thickness and echogenicity of the plantar fascia. J Clin Ultrasound.2012;40:14-19.

Referințe

DOCUMENTE SIMILARE

Using a case study designed for forecasting the educational process in the Petroleum-Gas University, the paper presents the steps that must be followed to realise a Delphi

Key Words: American Christians, Christian Right, Christian Zionism, US-Israel Relations, Conservative Christians Theology, State of Israel, Jews, Millennial beliefs,

The above results suggest two important conclusions for the study: The factors affecting the adoption of the de-internationalization strategy for both case A and case B,

According to nonverbal communication literature, the words we use effect 7%, our voice qualities (tone, pitch etc) 38%, while body language effects 55% on our

The number of vacancies for the doctoral field of Medicine, Dental Medicine and Pharmacy for the academic year 2022/2023, financed from the state budget, are distributed to

The longevity of amalgam versus compomer/composite restorations in posterior primary and permanent teeth: findings From the New England Children’s Amalgam Trial..

perivascular technique, where the operator blocks the musculocutaneous nerve separately and depos- its local anaesthetic solution around the axillary artery, which is in turn

The point-of-care ultrasound examination is per- formed by placing a high frequency linear transducer over the acromio-clavicular joint following the long axis of