• Nu S-Au Găsit Rezultate

(1)EVALUATION OF RESIN/SILICONE BASED ROOT CANAL SEALERS

N/A
N/A
Protected

Academic year: 2022

Share "(1)EVALUATION OF RESIN/SILICONE BASED ROOT CANAL SEALERS"

Copied!
9
0
0

Text complet

(1)

EVALUATION OF RESIN/SILICONE BASED ROOT CANAL SEALERS. PART I: PHYSICAL PROPERTIES

D. HELVACIOGLU YIGITa*, N. GENCOGLUa

aAssociate Professor, Department of Endodontics, Faculty of Dentistry, Kocaeli University, Kocaeli, Turkey

bProfessor, Department of Endodontics, Faculty of Dentistry, Marmara University, Istanbul, Turkey

The aim of this study was to evaluate the physical properties of EndoRez, Diaket, Epiphany, Roekoseal, Fibrefill, GuttaFlow, AHPlus, AH26 to that of a traditional zinc oxide based Kerr PCS sealers. Ten samples of each material were evaluated for flow, radiopacity, solubility and dimensional change tests according to ISO standards 2001- 6876. The findings were statistically analyzed. Radiopacity and solubility of all sealers were in accordance with ISO standards 6876, except dimensional stability. However, all sealers had expansion values above the ISO requirements. Epiphany sealer showed the greatest expansion and the most flow rates under the given condition (p<0.05). AH26 sealer was found to be the most soluble sealer (p<0.05). Although AHPlus sealer was found to be the most radiopaque sealer, the difference was not significant between AHPlus and Roekoseal, Epiphany and Kerr PCS (p>0.05). According to the result of this study, all root canal sealers showed acceptable properties due to ISO standards except dimensional stability.

(Received November 2, 2011; Accepted January 20, 2012)

Keywords: Root canal sealer, Flow, Radiopacity, Solubility, Dimensional changes

1. Introduction

One objective of root canal treatment is complete seal of the prepared canal system with root canal sealer in conjunction with a core material1. Root canal sealers are intended to fill the irregularities between the dentinal walls and the core material, as well as the accessory and lateral canals2,3. Root canal sealers should meet certain general requirements such as adequate flow and dimensionally stability, sufficient radiopacity, low solubility, qualified sealing ability and good biologic behaviour4. Physical characteristics of sealers could affect handling and clinical behaviour of the sealer, and this results, having an influence on the quality of the root canal filling 5-7.

Solubility is an undesirable characteristic because it may cause microleakage and dissolution of biologically incompatible components in the root canal8.

Dimensional change affects the integrity of the bond between the sealer and the root dentin or core material7. The irregularities of the root canals and presence of accessory canals make the flow characteristic of special interest. Sealers should flow into irregularities and lateral canals of the root canals without causing periapical extrusion9.

An ideal sealer must have sufficient radiopacity in order to be able to distinguish it from surrounding structures, to identify if it is in the canal or extruded into periapical tissue and to assess the quality of the root canal filling 10.

A number of tests have been described to assess the physical properties of sealers. These tests have been systemized by both International Standards Organization and ANSI/ADA standards11,12.

*Correspondence: [email protected], [email protected]

(2)

Zinc oxide-eugenol sealers are the most frequently used for many years. Despite a long history of successful usage,they have some disadvantages such as staining, slow setting time and solubility13.

Recently methacrylate resin sealers have been introduced, aiming to create “mono-block”

by the adhesion of the sealer to the thermoplastic polymer cone and the dentin walls of the root canal. Although so many studies have been published about sealing and adhesion properties of resin based sealer14-16, there is a few study published about physical properties of these sealers.

Therefore, the aim of this study was to evaluate the flow, solubility, dimensional change and radiopacity of eight resin and silicone-based sealers in comparison with a conventional zinc oxide-eugenol based sealer by using the methods proposed in the ISO standards.

2. Materials and methods

Flow, radiopacity, solubility, and dimensional change of nine different root canal sealers were measured according to the standards of ISO recommendations for dental root canal sealing materials 12.

Nine root canal sealers were evaluated in this study. The detailed information about the source and composition of these root canal sealers are listed in Table 1. The sealers were mixed according to the manufacturer’s instructions. Ten repetitions were performed for each canal sealer and the result was obtained by calculating the arithmetic mean.

Table 1: List of the root canal sealers, their composition and manufacturers

Sealer Composition Manufacturer

RoekoSeal Polydimethylsiloxane, silicone oil, parafin, hexachloride platinum acid, zirconium dioxide.

Roeko,Langenau, Germany

GuttaFlow Polydimethylsiloxane, silicone oil,

zirconium oxide, gutta-percha Roeko, Langenau, Germany Diaket Zincoxide, bismuth phosphate,

propionylacetophenone, copolymers of acetate, vinyl chloride, vinyl isobutyl ether, triethanolamine

ESPE, Seefeld, Germany

AH26 Bizmut oxide, methenamine, silver, titanyum oksit, bisphenol-A-diglycidylether

DeTrey/Dentsply, Konstanz, Germany

AH Plus Epoxy resins, zirconium oxide, iron oxide, calcium tungstate, silicone oil

DeTrey/Dentsply, Konstanz, Germany

EndoRez Urethane dimethacrylate resin , zinc oxide, barium sulphate, resin, pigment

Ultradent, South Jordan, UT, USA

Epiphany Bisphenol-A-glycidyldimethacrylate, polyethylene glycol dimethacrylate, ethoxylated bisphenol-A dimethacylate, urethane dimethacrylate, barium sulphate, silica, calcium oxide, bismuth, pigment

Pentron,LLC, Wallingford, CT, USA

FibreFill Benzoyl Peroxide, UDMA, HDDMA, BISGMA, PEGDMA, Proprietary Carboxylic Acid Functional Resins, Silane- Treated bariumborosilicate glasses, barium sulfate, calcium hydroxide, silica, pigment

Pentron, LLC, Wallingford, CT, USA

Kerr Pulp Canal

Sealer Zinc oxide, silver, resin thymol iodide,

eugenol, canada balsam Kerr Sybron,Romulus,MI,

USA

(3)

Flow: The center points of glass plates are marked with an acetate pen. 0.05 ml of the mixed sealer was placed on that center point of a glass plate with a graduated disposable 1 ml syringe (Ayset Plastik Teks. Elek. San. As., Adana, Turkey). At 3 mins after inception of mixing, a second glass plate and a load of 100 g was placed centrally on the top of the sealer. After seven minutes, the load was removed without moving the top glass plate from its place. The maximum and minimum diameters from the center point of the compressed disc of sealer were measured in mm using a digital caliper (Mitutoyo Corporation, Japan). If the difference between these measurements was within 1 mm, the average of the diameters were recorded as the flow rate.

Radiopacity: Ten acrylic plates containing nine wells with the diameter 5 mm and 1 mm thickness and a socket for aluminum step-wedge were prepared. The wells were filled with freshly mixed nine different root canal sealers. Another glass plate was placed on the sealers to ensure that the excess sealer was removed. Plates were kept at 37 ºC and 95 % relative humidity until completely set. An aluminum step-wedge with thickness varying from 1 to 12 mm (increasing 1 mm per step) had been placed on the plates for reference. Then each sample was radiographed by a dental X-ray machine (Trophy, Vincennes, France) operating at 70 kVp, 10 mA and 0.17 seconds.

The object-focus distance was 30 cm. Standardized images were obtained using phosphorstorage plates (PSPs) from the Digora (Orion Soredex, Helsinki, Finland) digital system. Mean grey values (MGV) of three different areas in each sample and each step of aluminum step-wedge were determined by an image program (Image ProPlus 4.0 Media Cybernetics Inc, Silver Spring, MD, USA). The average values were calculated for each material and aluminum step-wedge. A calibration curve was generated from the radiographic densities of corresponding aluminum steps for each sample by using a software (Curve Expert 1.3) Mean gray values of the materials were converted into equivalent mm Aluminum thickness by the means of formula derived from that curve.

Solubility: Moulds (diameter: 20 mm, height: 1,5 mm) filled with freshly mixed root canal sealers were placed on a glass plate covered with cellophane sheet. Another glass plate was pressed on the top of the sealers. Samples of Epiphany and EndoRez sealers were kept in the anaerobic chamber, and the other samples were transferred to regular chamber at 37 °C for 24 h.

The samples were removed from moulds, weighed using an analytical balance (AND HM-200, A&D Company Limited, MA, USA) with a degree of accuracy of 0,001 g and placed in petri dishes. Then, they were immersed in 50 ml distilled water and kept in 37 °C for 24 h. The weight change of specimens was recorded. The samples were removed and dried on absorbent paper and reweighed. The difference between two weights was calculated.

Dimensional Change: Cylindrical teflon moulds having a height of 12 mm and an internal diameter of 6 mm were placed on a glass plate covered by a cellophane sheet. The moulds were filled with the freshly mixed sealers until a slight excess of material was observed at the top.

Another glass plate wrapped in cellophane sheet was placed on top of the sealer. The mould and the plates were held together firmly in a C-clamp. Epiphany and EndoRez containing samples were transferred to the anaerobic chamber to allow setting process properly (16). Other samples were kept in regular chamber. All samples were kept in chamber at 37 °C for three times more than the setting time as recommended by the manufacturer. Regular surfaces were obtained by grinding the flat ends of the moulds by 600 grit wet sandpaper and then cylindrical samples (~12 mm height x 6 mm diameter) were removed from the moulds. The distance between the flat ends of each sample was measured by using a digital caliper with an accuracy of 0.01 mm (Mitutoyo Corporation, Japan). The samples were stored in distilled water at 37 °C for 30 days. They were dried and their length were measured again. The difference in length was calculated as a percentage of the original length. Mean of the ten replicates was recorded as dimensional change of the sealer.

The data were evaluated statistically using one way ANOVA and Tukey post hoc tests (p=0.05)

(4)

3. Results Flow:

The mean values of flow measurements for all root canal sealers were shown in Table 2.

The flow values varied from 4.03 mm (Kerr PCS) to 11.37 mm (Epiphany sealer).But statistically, only Kerr sealer showed significantly lower flow rate than the other sealers (p <0.05).

Table 2. Flow rates of root canal sealers Sealer Flow (mm) (mean±SD) GuttaFlow 7,96 ± 0,29

Roekoseal 6,31 ± 0,27

AH26 8,55 ± 0,27

AHPlus 9,50 ± 0,20 Kerr PCS 4,03 ± 0,23 Epiphany 11,37 ± 0,28 EndoRez 7,00 ± 0,34 Diaket 9,91 ± 0,38 FibreFill 6,35 ± 0,25

Radiopacity:

Table 3 shows the mean gray value (MGV) and equivalent aluminum thickness (mm) of each root canal sealer. Radiopacities were expressed in milimeters of aluminum and higher values represented greater radiopacity, ranging between 3,22 mmAl and 8,92 mmAl. All sealers possessed radiopacity above 3 mm of aluminum, complying with the ISO requirements.

Table 3. Radiopacity mean values of all sealers.

Radiopacity(MGV) (mean±SD)

Radiopacity value (mm Al)

(mean±SD) GuttaFlow 170,66±12,15 4,61±1,21

Roekoseal 200,42±9,01 7,06 ±1,37

AH26 165,84±31,41 4,68 ±2,56

AHPlus 214,42±12,15 8,92±1,34 Kerr PCS 209,87±14,88 8,02±2,08

Epiphany 214,78±17,21 8,59±2,48 EndoRez 192,93±13,03 6,45±1,27

Diaket 149,42±8,84 3,22±0,62 FibreFill 178,36±8,74 5,16±0,87

Although AHPlus sealer was found to be the most radiopaque sealer, but statistically only difference was found between GuttaFlow, AH 26, EndoRez, Fibrefill and Diaket sealer (p<0.05).

(5)

On the other hand, Diaket was found to be statistically less radiopaque than AHPlus, Roekoseal, Epiphany, EndoRez and Kerr PCS (p<0.05).

Solubility:

Average solubility (%) with standard deviation for the sealers is presented in Table 4 . All sealers showed values within the limits of ISO standards (weight loss ≤ 3 % of mass).

Table 4. Solubility rates (%) of root canal sealers.

Sealers Solubility (%) (mean±SD) GuttaFlow 0,249 ± 0,115 AH26 -0,617 ± 0,151 AHPlus 0,012 ± 0,013 KerrPCS 2,426 ± 0,733 Epiphany 1,319 ± 0,232 EndoRez 1,283 ± 0,191

Diaket 0,110 ± 0,055

FibreFill 1,689 ± 0,552

AH26 samples gained weight when immersed in water and was less soluble than the other sealers (p<0.05). Kerr PCS found to be was the most soluble sealer (p <0.05). EndoRez, Epiphany and Fibrefill sealers showed similar solubilities which were significantly greater than GuttaFlow, Roekoseal, AHPlus, and Diaket sealers(p<0.05). Statistically no difference was found amoung GuttaFlow, Roekoseal, AHPlus, and Diaket sealer (p>0.05).

Dimensional Change:

The dimensional change rates (%) for each root canal sealer were presented in Table 5.

None of the sealers conformed to the standards of ISO (shrinkage ≤ 1.0 %, expansion ≤ 0.1 %).

Although all sealers showed some expansion, Epiphany exhibited the most (p <0.05). AHPlus sealer showed the least expansion, but the difference was not significant between Roekoseal and Kerr PCS (p>0.05).

(6)

Table 5. The dimensional change rates (%) of root canal sealers.

Sealers D. stability (%) (mean±SD) GuttaFlow 1,185 ± 0,986 Roekoseal 0,356 ± 0,274

AH26 1,800 ± 0,978

AHPlus 0,314 ± 0,075 KerrPCS 0,419 ± 0,298 Epiphany 8,010 ± 1,151 EndoRez 2,132 ± 0,194 Diaket 0,571 ± 0,117 FibreFill 1,688 ± 0,303

4. Dıscussıon

ISO and ANSI/ADA11,12 have standardized some technological tests to investigate the physical properties of sealers. Assessment of the flow, radiopacity, solubility and dimensional change properties were evaluated using methods recomended by ISO in the present study12.

AH26 and AHPlus are both epoxy resin-based sealers. It’s indicated that, AHPlus possesses advantageous properties (such as lower solubility, less shrinkage, higher radiopacity and better biocompatibility and no formaldehyde release) than AH2617. In the present study, AHPlus showed to be more radiopacity and flow, and less expansion, compared to AH26 (p<0.05).

However AH26 was less soluble than AHPlus in 24 hour test period (p<0.05).

Flow characteristic is the consistency of the mixed sealer enabling it to reach narrow irregularities, lateral canals and the apical foramen4. Besides the difficulty to control the material during placement into the canal, high flow property may also result in extruded material over the apical foramen, compromising periapical healing9,18. Particle size, film thickness, temperature, rate of insertion, internal diameter of the canal, powder/liquid or paste/paste ratio and shear rate are the factors influencing the flow rate of root canal sealers5,19,20. The flow measurements of the root canal sealers vary widely because of the differences in the methods used in the studies. Vermilyea et al.21 used rotational viscometry, whereas Weisman 20 used simulated ultrafine canal. ISO standards stated that when a load of 120 g applied on a sealer disc, the disc should have a diameter not less than 20 mm12. The same method (with 100 g load) had been used in the present study and the sealer disc diameters range was between 4.03 mm-11.37 mm.

The variability of the results of flow studies also depends on powder/liquid or paste/paste ratio of the mixed material. For some materials very small changes in this ratio may cause a profound change in disc diameter19. Orstavik19 emphasized the need for manufacturers to provide measuring devices giving optimum powder/liquid or paste/paste ratio of root canal sealers. Most of the root canal sealers (Epiphany, Fiberfill, Roekoseal, GuttaFlow, EndoRez) were in two barrel automix syringes which were provided standard mixtures. The other sealers were mixed according to manufacturers directions.

(7)

New dual-cured resin-based sealers have been promoted with the desirable property of bonding strongly with both canal walls and the core filling materal and creating monoblocks within the root canal22. From this point of view, flow is a desirable property for resin-based sealers. Epiphany sealer showed the highest flow rate when compared to the others. This would provide well-adapted fillings and facilitate the formation of monoblock. High flow rate of resin- based sealers might also prevent polymerization contraction stresses. Thus shrinkage stresses on the canal walls during polymerization would be minimized23. The other sealers also showed acceptable flow rates in the present study.

The sealer must be radiopaque in order to detect the extention and the quality of the root canal filling. Beyer-Olsen&Orstavik10 established a standardized system to measure the quality of radiopacity. They used an aluminum step-wedge with 2 mm increments as a reference to determine the equivalent aluminum thickness of the studied materials. In literature usually, conventional radiographic films and optical densitometers were used to evaluate the radiopacity of filling materials10. However, in some studies, indirect method by converting the radiographs to digital images were also used instead of optical densitometer24,25. Meantime, imaging directly with digital X-ray systems are time saving, consistent and the quality of the radiographic images are satisfactory25. In the present study, digitally radiographed samples were evaluated with a image- analysis computer program. By digital radiography, standardization of the study was achieved easily. The images could be evaluated consistently by the software, without time consuming to stages of chemical proccessing of conventional films. Neither direct nor indirect digital systems are mentioned on the ISO standards, therefore a modified standard is needed for the radiopacity evaluation of root canal filling materials26. Rasimick et al.27 stated that the imaging technique could affect the measured radiopacity values of the materials. Barium and bismuth containing materials could have different radiopacities on film and phosphor store plates27. Also differences could be found in the aluminum alloy of the step-wedge, exposure time, focal film distance, kVp, and mAs affects the radiopacity measurements of materials in stu.

The radiopacity of root canal sealers should be at least 3 mmAl ,but excessive radiopacity of the material is not mentioned by ISO standardization12. The radioopacity rates of all sealers used in the present study were consistent with ISO standards. Radioopacity of AHPlus was found to be 8.92 mmAl, which exhibited the highest radiopacity of all sealers in this study. This findings collaborate previous studies results28,29. However no significant difference was found between AHPlus and Roekoseal, Epiphany and Kerr PCS (p>005). Radiopacity properties of AHPlus sealer was contributed to zirconium oxide and iron oxide content29. Epiphany sealer contains silane treated barium borosilicate glass, barium sulfate and bismuth which provides radiopacity. The radiopacity of Epiphany in this study was found 8.59 mmAl similar to previous study result30. Kerr PCS includes silver particles to improve the radiopacity. Beyer-Olsen &Orstavik10 found Kerr PCS more radiopaque than AH26 and Diaket sealer similar to our findings. Zirconium dioxide is the radiopaque ingredient for Roekoseal. Roekoseal has a radiographic density equivalent to 7.06 mmAl higher than the values reported in previous studies25,29.

Solubility is an undesirable property for a root canal sealer because it can cause the sealer to release components that may be biologically incompatible and formation of gaps can affect the hermetic seal of the root canal filling negatively. Because the sealers are commonly used with a core material, solubility of sealers do not constitute a clinical problem. However the solubility of sealer can negatively influence long-term seal of the root canal filling13. Major differences in sealing ability of the root canal sealers over the time, could be related to the solubility of the materials. In a study, the apical sealing ability of Epiphany was reduced after 16 months of water storage and this finding was correlated with the high solubility of Epiphany.

According to ISO standards the solubility of root canal sealers shouldn’t exceed 3% mass fraction12. All the root canal sealers studied were within this limit of solubility. Epiphany and EndoRez showed higher values than standards in previous report28. This might be because of hydrophilic nature of methacrylate resin-based sealers and the release of unreacted monomers22. These sealers require anaerobic conditions for polymerization and setting. An uncured layer has been observed in the aerobic environment16. In the present study, samples were placed in an anaerobic chamber to obtain polymerized sealer discs. The low solubility degree of methacrylate resin-based sealers might be a result of anaerobic conditions and optimal polymerization.

(8)

Both Epoxy resin-based sealers (AH26 & AHPlus) found to be the less soluble than other sealers in the present study. These finding is in agreement with the previous studies findings9,30. However, different test mediums or periods might effect the solubility assessment results.

The solublity rates of sealers in this study are consistent with those of Orstavik30 who found AH26 the least soluble with increased weight. The researcher found Kerr PCS more soluble than Diaket, N2, AH26, Procosol and Endomethasone. The stability of the epoxy resins and insolubility of silver powder and bismuth oxide provides insolubility of AH26. Instability of the zinc eugenolate chelate matrix on the other hand, is responsible for the increased solubility rate of Kerr PCS30.

Most root canal sealers shrink or expand as a result of setting. Dimensional change studies are important to show the potential of sealers to provide desired hermetic seal and bonding core materials to the dentinal walls. ISO standards recommend a maximum shrinkage of 1% or expansion of 0.1 % of the measured sample length for root canal sealers12. In the present study, expansion rates of all sealers were above those defined by the ISO. Water absorption of resin- based sealers during setting might explain the high expansion rates7,22. However water sorption and expansion have belated beneficial effects, compansating for the stresses developed on the canal walls during polymerization shrinkage22. Hydrophilic methacrylate resin-based sealer Epiphany showed the greatest dimensional change with 8 % expansion in accordance with the results of Hammad et al.6 reported that polymerization shrinkage after setting is a serious problem for resin-based sealers. According to the present study results, all resin-based sealers showed extreme expansion rates. More extensive research should be conducted to investigate the long term dimensional characteristics of resin-based sealers.

Resin-based sealers are gaining popularity with enhanced adhesive properties. However there are limited studies on their physical properties. Further investigations are required to clarify the relevance of compositions and ingredients of sealers with the physical properties. Also investigations should be directed toward the clinical consequences of the physical properties for successful root canal treatment.

Acknowledgement

This study was supported by Marmara University, Research Fund.

References

[1] Sundqvist G, Figdor D, Persson S, Sjögren U. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 85, 86-93. (1998)

[2] Langeland K. Root canal sealants and pastes. Dent Clin North Am; 18, 309 (1974).

[3] Schilder H. Filling Root Canals in Three Dimensions. J Endod,32, 281. (2006)

[4] Grossman LI. Endodontic Practice. 8th ed. Philadelphia: Lea & Febiger, 1974: 282-323.

[5] Grossman LI. Physical properties of root canal cements. J Endod 2,166-75. (1976)

[6] Hammad M, Qualtrough A, Silikas N. Extended setting shrinkage behaviour of endodontic sealers. J Endod 34,90 (2008).

[7] Kazemi RB, Safavi KE, Spångberg LS. Dimensional changes of endodontic sealers. Oral Surg Oral Med Oral Pathol 76,766. (1993)

[8] Carvalho-Junior JR, Guimaraes LFL, Correr-Sobrinho L, Pecora JD, Sousa-Neto MD.

Evaluation of solubility, disintegration, and dimensional alterations of a glass ionomer root canal sealer. Braz Dent J,14,114-8. (2003)

[9] McMichen FR, Pearson G, Rahbaran S, Gulabivala K. A comparative study of selected physical properties of five root-canal sealers. Int Endod J 36,629 (2003)

[10] Beyer-Olsen EM, Orstavik D. Radiopacity of root canal sealers. Oral Surg Oral Med Oral Pathol,51, 320 (1981)

[11] ANSI/ADA Specification no. 57 for endodontic filling materials J Am Dent Assoc, 108, 88 (1984)

(9)

[12] International Standards Organization. ISO 6876:2001 Dental root canal sealing materials 2nd ed. 2004:1-10.

[13] Torabinejad M, Walton RE, Endodontics Principles and Practice, 4th ed, St.Louis,Saunders 304, 2009

[14] Wennberg A, Orstavik D. Adhesion of root canal sealers to bovine dentine and gutta-percha.

Int Endod J, 23,13.(1990)

[15] Lee KW, Williams MC, Camps JJ, Pashley DH. Adhesion of endodontic sealers to dentin and gutta-percha. J Endod,28,684 (2002)

[16] Kardon BP, Kuttler S, Hardigan P, Dorn SO. An in vitro evaluation of the sealing ability of a new root-canal-obturation system. J Endod 29,658-61. (2003)

[17] http://www.dentsply.eu/bausteine.net/file/showfile.aspx?downdaid=7299 &sp=D&domid=1042&fd=2.

[18] Sjögren U, Hagglund B, Sundqvist G, Wing K. Factors affecting the long-term results of endodontic treatment. J Endod 16, 498 (1990)

[19] Orstavik D. Physical properties of root canal sealers: measurement of flow, working time, and compressive strength. Int Endod J 16,99 (1983)

[20] Weisman MI. A study of the flow rate of ten root canal sealers. Oral Surg Oral Med Oral Pathol,29,255 (1970)

[21] Vermilyea SG, de Simon LB, Huget EF. The rheologic properties of endodontic sealers. Oral Surg Oral Med Oral Pathol 46,711 (1978)

[22] Kim YK, Grandini S, Ames JM, Gu LS, Kim SK, Pashley DH, et al. Critical review on methacrylate resin-based root canal sealers. J Endod, 36,383 (2010)

[23] Davidson CL, DeGee AJ. Relaxation of polymerization contraction stresses by flow in dental composites. J Dent Res 63,146 (1984)

[24] Gambarini G, Testarelli L, Pongione G, Gerosa R, Gagliani M. Radiographic and rheological properties of a new endodontic sealer. Aust Endod J, 32,31 (2006)

[25] Tagger M, Katz A. Radiopacity of Endodontic Sealers: Development of a New method for Direct measurement. J Endod,29,751 (2003)

[26] Sabbagh J, Vreven J, Leloup G. Radiopacity of resin-based materials measured in film radiographs and storage phosphor plate (Digora). Oper Dent,29,677 (2004)

[27] Rasimick BJ, Shah RP, Musikant BL, Deutsch AS. Radiopacity of endodontic materials on film and a digital sensor. J Endod 33,1098 (2007)

[28] Resende LM, Rached-Junior FJ, Versiani MA, Souza-Gabriel AE, Miranda CE, Silva-Sousa YT,et al. A comparative study of physicochemical properties of AH Plus, Epiphany, and Epiphany SE root canal sealers. Int Endod J 42,785-93. (2009)

[29] Tanomaru JMG, Cezare, Gonçalves M, Tanomaru-Filho M. Evaluation of the radiopacity of root canal sealers by digitization of radiographic images. J Appl Oral Sci,12,355 (2004) [30] Orstavik D. Weight loss of endodontic sealers, cements and pastes in water. Scand J Dent Res,91(4),316 (1983)

Referințe

DOCUMENTE SIMILARE

The averaging theory is one of the most powerfrrl tools in approaching problems governed by differential equations, The goal of this note is to present a theoretical

A pendant drop test was carried to study the effect of Zinc Oxide (ZnO) based nanofluid on Interfacial tension (IFT) reduction.. Firstly, the solution was prepared as stated

The tribological behavior of different carbonaceous nanomaterials such as single wall carbon nanotubes (SWNTs), functionalized single wall carbon nanotubes (SWNTf), multiwall

The objective of this study was to evaluate the effect of direct heat-based hydro distillation (DHBH) and in-direct heat-based hydro-distillation (IDHBH) methods

De¸si ˆın ambele cazuri de mai sus (S ¸si S ′ ) algoritmul Perceptron g˘ ase¸ste un separator liniar pentru datele de intrare, acest fapt nu este garantat ˆın gazul general,

The modification of the promotion criteria in the area of medical university education triggered an increase in the number of articles published by the

According to our previous investigations it seems that tolerance, whether regarded as a political practice or a philosophical or moral principle, is a strategy (or tactics) of one

The number of vacancies for the doctoral field of Medicine, Dental Medicine and Pharmacy for the academic year 2022/2023, financed from the state budget, are distributed to